DC Chargers

30kW DC Charger

FEATURES

advanced divider
30 kW DC Charger

Specifications

Rated power TP5-30-480
Input 480VAC (3P+N+PE), 60Hz
Output Voltage 150-1000VDC
Output Current 0 to 100A
FLA || Breaker Rating 40A || 64 A
Power factor > 0.98
Efficiency >94%
Connectors CCS1 Or CHAdeMO
Connector cable length 5m
Weight 176 lbs (80kgs)
Dimensions (L x D x H) 21’’ x 12’’ x 27’’
Charging Protocol Standards Mode 4 - IEC-61851, ISO-15118, DIN 70121
Mode 4 - CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 7’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

60kW DC Chargers

FEATURES

advanced divider
60 kW DC Charger

Specifications

Rated power TP3-60-480 TP5-60-480
Input 480VAC (3P+N+PE), 60Hz
Output Voltage 150-500VDC 150-1000VDC
Output Current 0 to 140A
FLA || Breaker Rating 80A || 100A
Power factor > 0.98
Efficiency >94%
Connectors CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
Cyclic Charge Mode CCS1 - 140 A || CHAdeMO – 125 A
Parallel Charge Mode (Optional) 30 kW per Port
Connector cable length CCS - 16 ft (5 m)
CHAdeMO - 16ft (5 m)
Weight 530 lbs (240kgs)
Dimensions (L x D x H) 29’’ x 19’’ x 72’’
Charging Protocol Standards Mode 4 - IEC-61851, ISO-15118, DIN 70121
Mode 4 - CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card - Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

120kW DC Chargers

FEATURES

advanced divider
120 kW DC Charger

Specifications

Rated power TP4-120-480 TP5-120-480
Input 480VAC (3P+N+PE), 60Hz
Output Voltage 150-750VDC 150-1000VDC
Output Current 0 to 200A
FLA || Breaker Rating 160A || 200A
Power factor > 0.98
Efficiency >94%
Connectors CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
Cyclic Charge Mode CCS1 - 200 A || CHAdeMO – 125 A
Parallel Charge Mode (Optional) 60 kW per Port
Connector cable length CCS1 - 16 ft (5 m)
CHAdeMO - 16ft (5 m)
Weight 840 lbs (380kgs)
Dimensions (L x D x H) 29’’ x 26.5’’ x 72’’
Charging Protocol Standards Mode 4 - IEC-61851, ISO-15118, DIN 70121
Mode 4 -  CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card - Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

160kW DC Chargers

FEATURES

advanced divider
160 kW DC Charger

Specifications

Product # TP5-160-480 HPC-160-480
Maximum Power 160 kW
Output Voltage 150 – 1000 VDC
Max Output Current upto200A upto400A
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 215A || 300A
Power Factor >0.98
Efficiency >94%
  Connector Options CCS1 and CCS1
CCS1 and CHAdeMO
CCS1
CCS1 and CCS1
CCS and CHAdeMO
CCS Cable 200A 400A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 160kW (Max :200A) 1 x 160kW (Max : 400A)
Parallel Mode 2 x 80kW 2 x 80kW
Connector cable length CCS - 16 ft (5 m)
 CHAdeMO -16ft (5 m)
CCS - 13 ft (4 m)
 CHAdeMO -16ft (5 m)
Weight 880 lbs (400 kg) 950 lbs (430 kg)
Dimensions (L x D x H) 29.5‘’ x 26.5’’ x 73’’ 29.5‘’ x 26.5’’ x 73’’
Charging Protocol Standards Mode 4, IEC-61851, ISO-15118, DIN 70121
Mode 4, CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card - Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007,EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

180kW DC Chargers

FEATURES

advanced divider
180 kW DC Charger

Specifications

Product # TP5-180-480 HPC-180-480
Maximum Power 180 kW
Output Voltage 150 – 1000 VDC
Max Output Current upto 200A upto 500A
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 240A || 300A
Power Factor >0.98
Efficiency >94%
Connector Options CCS1 and CCS1
CCS1 and CHAdeMO
CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 200A 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 180kW (Max: 200A) 1 x 180kW (Max: 450A)
Parallel Mode 2 x 90kW (Max: 200A) 2 x 90kW (Max: 250A)
Connector cable length CCS1 - 13 ft (4 m) | CHAdeMO – 16ft (5 m)
Weight 880 lbs (400 kg) 950 lbs (430 kg)
Dimensions (L x D x H) 29.5‘’ x 26.5’’ x 73’’
Charging Protocol Standards Mode 4, IEC-61851, ISO-15118, DIN 70121
Mode 4, CHAdeMO 0.9, 1.0
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007,EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

240kW DC Charger

FEATURES

advanced divider
240 kW DC Charger

Specifications

Product # HPC-200-480
Maximum Power 240 kW
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 320A || 400A
Output Voltage 150 – 1000 VDC
Max Output Current upto 500A
Power Factor >0.98
Efficiency >94% at nominal output power
Connector Options CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 240kW (Max: 500A)
Parallel Mode 2 x 120kW (Max: 250A)
Charing Standard - 1 Mode 4 - IEC-61851, ISO-15118, DIN 70121
Charing Standard - 2 Mode 4 - CHAdeMO 0.9, 1.0
Connector cable length CCS1 - 13 ft (4 m) | CHAdeMO – 16ft (5 m)
Weight 950 lbs (430 kg)
Dimensions (L x D x H) 41‘’ x 35’’ x 74’’
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card - Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

300kW DC Charger

FEATURES

advanced divider
300 kW DC Charger

Specifications

Product # HPC-300-480
Maximum Power 300 kW
Input Voltage || Frequency 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 400A || 450A or 500A
Output Voltage 150 – 1000 VDC
Max Output Current upto 600A
Power Factor >0.98
Efficiency >94% at nominal output power
Connector Options CCS1
CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 300kW (Max:500A)
Parallel Mode 2 x 150kW (Max:300A)
Charing Standard - 1 Mode 4, IEC-61851, ISO-15118, DIN 70121
Charing Standard - 2 Mode 4, CHAdeMO 0.9, 1.0
Connector cable length CCS1 - 13 ft (4 m) | CHAdeMO – 16ft (5 m) with Cable Retractors
Weight 1170 lbs (530 kg)
Dimensions (L x D x H) 41‘’ x 35’’ x 74’’
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S, IK10
Operating temperature -22 deg F to 131 deg F (-30 deg C to 55 deg C)
Altitude < 6600ft (2000m)
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing)
Display 10’’ touch screen
Communication Protocol OCPP 1.6J
Access Control RFID: ISO/IEC 14443A/B || Credit Card - Optional
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012
Communication Ethernet, 4G/Wi-Fi
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge Protection 20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

360kW DC Charger

FEATURES

advanced divider
360 kW DC Charger

Specifications

Product Number HPC-360-480
Maximum Power 360 kW
Output Voltage 150 – 1000 VDC
Max Output Current Up to 500A
Input 480V (3P + N + PE) || 60 Hz
Input Current || Breaker Rating 480A || 600A
Power Factor >0.98
Efficiency >94% at nominal output power
Connector Options CCS1 and CCS1
CCS1 and CHAdeMO
CCS Cable 500A Liquid Cooled
CHAdeMO Cable 125A (Standard) Or 200A
Cycle Mode 1 x 360kW (Max: 500A)
Parallel Mode 2 x 180kW (Max: 400A)
Charging Protocol Standards Mode 4,IEC-61851,ISO-15118,DIN 70121 || Mode 4, CHAdeMO
0.9,1.0
Connector cable length CCS - 13 ft (4 m) | CHAdeMO – 16ft (5 m)
Cable Retractor Included
Weight 992 lbs (450 kg)
Dimensions (L x D x H) 41‘’ x 35.5’’ x 90’’
Insulation (input – output) >2.5 kV
Ingress Protection NEMA 3S (IP54), IK10
Altitude <6,600ft (2,000m)
Operating temperature -30°C to 55°C (-22°F to 131°F )
Working || Storage Humidity ≤ 95% RH || ≤ 99% RH (Non-condensing
Display 10’’ touch screen
Communication || Protocol Ethernet, 4G/WiFi || OCPP 1.6J
Access Control RFID : ISO/IEC 14443A/B | Credit Card Reader (Optional)
Metering DC kWh meter per each connector
Power Electronics Cooling Air Cooled
Regulatory Compliance UL-2202 || EMC: EN 61000-6-1:2007, EN 61000-6-
3:2007/A1:2011/AC:2012
Electrical Safety: GFCI RCD 20 mA Type A
Electrical Safety: Surge
Protection
20 kA
Electrical Safety General Over Voltage, Under Voltage, Over Current, Missing Ground
Electrical Safety: Output Short Output power disabled when output is short circuited
Electrical Safety Temperature Temperature Sensors @ Charge Coupler and Power Electronics
Emergency Stop Disables output power with emergency stop button

30kW to 120kW

30kw Wallbox Charger
30KW TO 60KW
120KW

High Power Chargers

60KW
180KW
200KW
300KW
350KW