Tellus Power Green DC Fast Charger
| Product# | TP5-60-480 |
| Model# | TP-EVPD-60kW |
| Input | 480VAC (3P+N+PE) || 60Hz |
| Output Voltage | 200 - 1000VDC |
| Output current | 0 to 150A |
| FLA || BreakerRating | 80A || 100A |
| Connectors | CCS1 / NACS / CHAdeMO (Dual Connector) |
| Cyclic Charge Mode | CCS1 / NACS-150A || CHAdeMO – 125A |
| Parallel Charge Mode | 30 kW per Port |
| Efficiency | ≥94% at nominal output power |
| Power factor | >0.98 |
| Display | 10’’touchscreen |
| Access Control | RFID : ISO/IEC 14443A/B | Credit Card Reader (Optional) |
| Metering | DC kWh meter pereach connector |
| Operating temperature | -22°Fto131°F (-30°Cto55°C) |
| Altitude | 6500’(2000m) |
| Working || Storage Humidity | ≤ 95% RH || ≤99% RH (Non-condensing) |
| Dimensions (L x D x H) | 29.5’’x 22.5’ ’x 72’’ |
| Protective Class | NEMA 3S (IP54), IK10 |
| Cooling system | Air cooling fans |
| Weight | 617 lbs (280kgs) |
| Compliance | UL and CE Certified |
| DC Charge System | Mode4-IEC-61851, ISO-15118, DIN70121 Mode 4 - CHAdeMO 0.9, 1.0 |
| Charging cable | 16ft (5m), Cable Retractor Included |
| Communication || Protocol | Ethernet, 4G/WiFi || OCPP 1.6J |
| Electrical Safety: GFCI | RCD 20 mA Type A |
| Electrical Safety: Surge Protection | 20 kA |
| Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
| Electrical Safety: OutputShort | Output power disabled when output is short circuited |
| Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
| Emergency Stop | Emergency Stop Button Disables Output Power |
| Regulatory Compliance | UL-2202 || EMC: EN 61000-6-1:2007, EN61000-6-3:2007/A1:2011/AC:2012 |