Rated power | TP4-30-480 |
Input | 400VAC / 480VAC (3P+N+PE) |
Frequency | 50Hz || 60Hz |
Output Voltage | 150 to 750VDC |
Output Current | 0 to 80A |
Power factor | > 0.98 |
Efficiency | ≥94% at nominal output power |
Connectors | CCS2, CHAdeMO, GB/T |
Connector cable length | 5m |
Weight | 80kgs |
Dimensions (L x D x H) | 21’’ x 12’’ x 27’’ |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - CHAdeMO 0.9, 1.0 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | -30 deg C to 55 deg C |
Altitude | < 2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ touch screen |
Interface protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Optional | Ethernet Standard || 4G/Wi Fi (Optional) |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Emergency Stop Button Disables Output Power |
Product Number | TP4-60-400 |
Input | 400VAC / 480VAC (3P+N+PE), 50/60Hz |
Output Voltage | 150-750VDC |
Output current | 0 to 150A |
Power factor | > 0.98 |
Efficiency | ≥94% at nominal output power |
Connectors | CCS2, CHAdeMO, GB/T Single and Dual |
Cyclic Charge Mode | CCS2 - 150 A || CHAdeMO – 125 A || GB/T – 150A |
Parallel Charge Mode (Optional) | 30 kW per Port |
Connector cable length | 5m |
Weight | 530 lbs (240kgs) |
Dimensions (L x D x H) | 736mm x 482mm x 1830mm |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - CHAdeMO 0.9, 1.0 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | -30 deg C to 55 deg C |
Altitude | <2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ LCD with touch screen |
RFID system | ISO/IEC 14443A/B |
Dimensions (L x D x H) | 736mm x 482mm x 1830mm |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard || 3G/4G Modem (optional) |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Disables output power with emergency stop button |
Product Number | TP4-120-400 |
Input | 400VAC / 480VAC (3P+N+PE) |
Frequency | 50 / 60Hz |
Output Voltage | 150-750VDC |
Output current | 0 to 200A |
Power factor | > 0.98 |
Efficiency | ≥94% at nominal output power |
Connectors | CCS2, CHAdeMO, GB/T *Option for Dual and Triple |
Cyclic Charge Mode | CCS2 - 200 A || CHAdeMO – 125 A || GB/T – 200A |
Parallel Charge Mode (Optional) | 60 kW per Port |
Connector cable length | 5m |
Weight | 380kgs |
Dimensions (L x D x H) | 29’’ x 22’’ x 72’’ |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - CHAdeMO 0.9, 1.0 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | -30 deg C to 55 deg C |
Altitude | <2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ LCD with touch screen |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Dimensions (L x D x H) | 29’’ x 22’’ x 72’’ |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard, 4G/Wi Fi Optional |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Emergency Stop Button Disables Output Power |
Product Number | TP4-160-400 |
Input Voltage | 400VAC / 480VAC (3P+N+PE) |
Frequency | 50/60 Hz |
Output Voltage | 150-750 VDC |
Output current | 0 to 250A |
Power factor | > 0.98 |
Efficiency | >94% at nominal output power |
Connectors | CCS2, CHAdeMO, GB/T *Dual or Triple Connectors Option Available |
Cyclic Charge Mode | CCS2 - 200 A || CHAdeMO – 125 A || GB/T – 250A |
Parallel Charge Mode (Optional) | 80 kW per Port |
Connector cable length | 5m |
Weight | 430kgs |
Dimensions (L x D x H) | 29’’ x 22’’ x 72’’ |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - CHAdeMO 0.9, 1.0 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | -30 deg C to 55 deg C |
Altitude | <2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ touch screen |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard || 4G/Wi Fi (Optional) |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Disables output power with emergency stop button |
Product Number | TP4-200-400 |
Maximum Power | 200 kW |
Input Voltage || Frequency | 400VAC / 480VAC (3P+N+PE), 50/60Hz |
Input Current || Breaker Rating | 0 to 300A |
Output Voltage | 150 - 750 VDC |
Output current | 0 to 300A (200A | 250A Limited by Connector) |
Power factor | > 0.98 |
Efficiency | >94% at nominal output power |
Connectors | Dual GB/T Dual CCS |
Cyclic Charge Mode | CCS - 200 A || GB/T – 250A |
Parallel Charge Mode | 100 kW per Port |
Connector cable length | 5m |
Weight | 430kgs |
Dimensions (L x D x H) | 760 mm x 673 mm x 1800mm |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | - 22 F to 131 F ( 30 C to 55 C ) |
Altitude | < 2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ touch screen |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard 4G || Wi Fi (Optional) |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Disables output power with emergency stop button |
Product Number | TP4-300-400 |
Maximum Power | 300 kW |
Input Voltage || Frequency | 400VAC || 480V (3P + N + PE) || 50/60 Hz |
Output Voltage | 150 - 750 VDC |
Output current | 0 to 400A (200A | 250A Limited by Connector) |
Power factor | > 0.98 |
Efficiency | >94% at nominal output power |
Connectors | Dual CCS Or Dual GB/T |
Cyclic Charge Mode | CCS2 - 200 A || GB/T – 250A |
Parallel Charge Mode (Optional) | 150 kW per Port |
Connector cable length | 5m |
Weight | 560kgs |
Dimensions (L x D x H) | 830mm x 1000mm x 2000mm |
Charging Protocol Standards | Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - GB/T 18487 2015, GB/T 20234 2015, GB/T 27930 2015 |
Insulation (input – output) | >2.5 kV |
Ingress Protection | IP54, IK10 |
Operating temperature | - 22 F to 131 F ( 30 C to 55 C ) |
Altitude | <2000m |
Working || Storage Humidity | ≤ 95% RH || ≤ 99% RH (Non-condensing) |
Display | 7’’ touch screen |
Communication Protocol | OCPP 1.6J |
Access Control | RFID: ISO/IEC 14443A/B || Credit Card - Optional |
Power Electronics Cooling | Air Cooled |
Regulatory Compliance | CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012 |
Communication | Ethernet Standard 4G || Wi Fi (Optional) |
Electrical Safety: GFCI | RCD 30 mA Type A |
Electrical Safety: Surge Protection | 20 kA |
Electrical Safety General | Over Voltage, Under Voltage, Over Current, Missing Ground |
Electrical Safety: Output Short | Output power disabled when output is short circuited |
Electrical Safety Temperature | Temperature Sensors @ Charge Coupler and Power Electronics |
Emergency Stop | Disables output power with emergency stop button |
© 2021 Tellus Power Green. All Rights Reserved. | Website Design by Rify Hosting